Looks like you are not TradeKey.com's Member yet. Signup now to connect with over 10 Million Importers & Exporters globally.
Join Now, its Free |
BOOK A CALL
Book Call On Your Favorite Time

By Signing Up. I agree to TradeKey.com Terms of Use, Privacy Policy, IPR and receive emails related to our services

Contact Us
product
Prev
hot runner heater controller
Next

hot runner heater controller

FOB Price

Get Latest Price

0 ~ 210

|

1 Piece Minimum Order

Country:

China

Model No:

016

FOB Price:

0 ~ 210 Get Latest Price

Place of Origin:

China

Price for Minimum Order:

-

Minimum Order Quantity:

1 Piece

Packaging Detail:

strong carton

Delivery Time:

2 weeks

Supplying Ability:

30000 Piece per Year

Payment Type:

T/T

Product Group :

-

Contact Now
Free Member

Contact Person Ms. Cherry

Xinqian, Taizhou, Zhejiang

Contact Now

Product Specification

  • color:silver
  • Enter attribute here - e.g. Color:Enter value here - e.g. Red
  • Enter attribute here - e.g. Color:Enter value here - e.g. Red
  • Enter attribute here - e.g. Color:Enter value here - e.g. Red
  • Enter attribute here - e.g. Color:Enter value here - e.g. Red
  • Enter attribute here - e.g. Color:Enter value here - e.g. Red
  • Enter attribute here - e.g. Color:Enter value here - e.g. Red
  • Enter attribute here - e.g. Color:Enter value here - e.g. Red
  • Enter attribute here - e.g. Color:Enter value here - e.g. Red
  • Enter attribute here - e.g. Color:Enter value here - e.g. Red

Product Description


Operate:
1.      1Open power switch and turn into working condition preset by manufacturer.
 (2)Press 【▲】【▼】to adjust temperature..
(3)Press 【SET】to check output percent..            
(4)Press 【SET】to check output electricity.
(5)Press 【MODE】to switch automatic, manual and standby mode.
(6)Manual mode: press 【▲】【▼】to adjust output percent.
(7)Restore factory setting: press 【MODE】whilst holding the 【SET】to power off, reboot can restore factory setting.
(8)Automatic mode: operating mode in generally working condition, the controller control the temperature in accordance with setting temperature.
(9)Manual mode: in particular cases (such as thermocouple fault), can provide appropriately output setting to switch to manual mode and maintain equipments operation until correct the fault. Press 【MODE】one minute to start manual mode, press 【▲】【▼】to adjust output percent.
*0Soft start mode: A. Prevent the heater strip wetted, and the heater will be damaged by over electricity. The heater strip is dehumidifier by using soft start mode (dehumidifier) function in low voltage condition.
B. Test thermocouples and heaters in low electricity when starting up.
 
Menu setting: press 【MODE】twice, one minute per time and enter into standby mode, the standby indicator lights up. Then, press SET key to start menu setting.
(1)Menu set by user
Press 【SET】to start menu.
Press 【SET】parameter of the layer.
Use 【▲】【▼】to switch parameters.
Press【MODE】to save and log out menu when complete setting.
The menu page is shown on PV screen; setting number is shown on SV screen.
PG1
Thermocouple type choice.
press【▲】to choose J-type thermocouple, SV shows J.
press【▼】 to choose K-type thermocouple, SV shows K.
press【SET】to go to next page or press【MODE】to save and log out menu.
PG2
Set temperature unit.
press【▲】to choose Celsius as temperature unit, SV shows C.
press【▼】 to choose Fahrenheit as temperature unit, SV shows F
press【SET】to go to next page or press【 MODE 】to save and log out menu
PG3
Set high temperature alarm.
When temperature is higher than set, high temperature alarm will start, PV screen will
show H I and sound alarm call. At the same time cut off output.
press【▲】【▼】to set the number with ****9. The factory value is **0.
press【SET】to go to next page or press【 MODE 】to save and log out menu
PG4
Set low temperature alarm.
When temperature is lower than set, low temperature alarm will start, PV screen will show
L O and sound alarm call. At the same time cut off output.
press【▲】【▼】 to set the number with ****0. The factory value is **0.。
press【SET】to go to next page or press【 MODE 】to save and log out menu
PG5
Set soft start mode output time.
press【▲】【▼】to set the soft start tome with ***0min, factory value is 4 min .
the actual temperature reach or over *3°C//**0°F, it will enter into【automatic mode】,soft start
function won’t work any longer.
Don’t change soft start mode ratio without special circumstances.
press【SET】to go to next page or press【 MODE 】to save and log out menu
 Wrong indication meter                           set factory value
No.
menu
Set value
1
Set thermocouple type
J
2
Set temperature unit
°C
3
Alarm buzzer
ON
4
High temperature alarm
*0°C
5
Low temperature alarm
**0°C
6
Soft start mode output time
4 minutes
7
Manual output percent

Country: China
Model No: 016
FOB Price: 0 ~ 210 Get Latest Price
Place of Origin: China
Price for Minimum Order: -
Minimum Order Quantity: 1 Piece
Packaging Detail: strong carton
Delivery Time: 2 weeks
Supplying Ability: 30000 Piece per Year
Payment Type: T/T
Product Group : -

Send a direct inquiry to this supplier

To:

Ms. Cherry < ANOLE INJECTION TECHNOLOGY CO., LTD >

I want to know: